Replacement power and audio output transformers for Fender Champ 5F1 amplifiers from 1956 to 1964.
$0.00

Fender Champ 5F1.
The Fender Champ is a 5 watt single ended class "A" guitar amplifier. A negative feedback loop was also added. Model 5F1 had had the filter choke removed from the circuit.

Power Transformer
The XPWR283 power transformers were specially designed and built for this amplifier. It come in a 120V 60 Hz., 230V 50/60Hz., or 230V50/60Hz. to 650V (325-0-325) at 100mA center tapped, 6.3V at 2.25A, and 5V at 3A.

Audio Output Transformer
The CXSE5 5K is a 5W, single ended tube output transformer for 7K Ohms to 4, 8 or 16 Ohms.

Magnet Wire
All units are wound with the finest virgin copper magnet wire. All windings use heavy insulated wire to provide excellent manufacturing yield, lower customer cost and superior life.

The Core
EDCOR uses the finest M6 line grain oriented steel cores. Each unit is hand stacked to assure at least 92% stack.

The Bobbin
EDCOR's standard bobbin with black finishing tape.

Termination
The terminations are UL1015, 20 ga. lead wire for the XPWR283 and UL1015, 20 ga. lead wire for the CXSE5 7K.

Mounting
These transformers are designed to replace the orginal stock transformers. You should still check to make sure that the dimensions of the transformers will fit in the space in your amplifier.

Fender Champ 5F1.
The Fender Champ is a 5 watt single ended class "A" guitar amplifier. A negative feedback loop was also added. Model 5F1 had had the filter choke removed from the circuit.

Power Transformer
The XPWR283 power transformers were specially designed and built for this amplifier. It come in a 120V 60 Hz., 230V 50/60Hz., or 230V50/60Hz. to 650V (325-0-325) at 100mA center tapped, 6.3V at 2.25A, and 5V at 3A.

Audio Output Transformer
The CXSE5 5K is a 5W, single ended tube output transformer for 7K Ohms to 4, 8 or 16 Ohms.

Magnet Wire
All units are wound with the finest virgin copper magnet wire. All windings use heavy insulated wire to provide excellent manufacturing yield, lower customer cost and superior life.

The Core
EDCOR uses the finest M6 line grain oriented steel cores. Each unit is hand stacked to assure at least 92% stack.

The Bobbin
EDCOR's standard bobbin with black finishing tape.

Termination
The terminations are UL1015, 20 ga. lead wire for the XPWR283 and UL1015, 20 ga. lead wire for the CXSE5 7K.

Mounting
These transformers are designed to replace the orginal stock transformers. You should still check to make sure that the dimensions of the transformers will fit in the space in your amplifier.

Products specifications
Bobbin Material Nylon 6/6 GF-30
Flammability Rating Class B 130°C
Core Material M-6 29 ga. grain oriented lamination steel
Termination UL1015, 20 & 18 ga. lead wire
Mounting See model for information.
Compliance RoHS & REACH
Write your own review
  • Only registered users can write reviews
  • Bad
  • Excellent
Products specifications
Bobbin Material Nylon 6/6 GF-30
Flammability Rating Class B 130°C
Core Material M-6 29 ga. grain oriented lamination steel
Termination UL1015, 20 & 18 ga. lead wire
Mounting See model for information.
Compliance RoHS & REACH