EDCOR EI625 x 0.625 in. 12 pin PCB mounted transformer with copper shield  reference image
EDCOR Audio Matcher XS4400 - 1/2W Quad-filar 1:1:1:1 matching transformer.

EDCOR Electronics Corporation

XS4400 - 1/2W Quad-filar 1:1:1:1 matching transformer.

Sale price$96.00 CAD

Duties, taxes, and shipping calculated at checkout.

SKU: XS4400

Quantity:
Quantity Discounts
10 pcs 25 pcs 100 pcs 500+ pcs
5% off 10% off 15% off 20% off
Orders over 25 pcs may take longer. Please contact us for scheduling and dates.

The XS4400 is a multi-purpose quad-filer balanced or unbalanced line level isolation matching transformer.  It has a turns ratio of 1:1:1:1.

Basic Specifications

Series
XS Series
SKU
XS4400
Schematic (PDF)
Download file
Spec Sheet (PDF)
Download file
Wattage
0.5W
Primary (input)
Line Level
Secondary (output)
Line Level
Turns Ratio
1:1:1:1
Static Shielding
Tin-plated copper EMI shielding tape
Termination
12 pin TH PCB
Mounting Orientation
Laydown (Z-Mount)

Primary (input)

Voltage
7.5V Max
DC Resistance
116Ω

Secondary (output)

DC Resistance
116Ω, 116Ω, and 116Ω

Other Specifications

Frequency Response
20~20KHz.,
Insertion Loss
<0.5dB
Winding Configuration
Quad-Filar

Physical

Weight
0.5 lb
Dimensions
1.88 in. (W) X 1.34 in. (H) X 1.54 in. (D)
Dimensional Drawing (#)
15000-EI063-063-P12
Dimension Drawing (PDF)
Download file
3D Model (STEP)
Download file

Material

Bobbin Material
Nylon 6/6 GF-30
Bobbin Flammability Rating
Class-HB
Magnet Wire
Nylon coated solid copper wire
Coil Finish Wrapper
Polyester film electrical tape
Termination
12 pin TH PCB
Core Material
M6 29 ga. steel lamination
Core Material Size
EI-625
Core Stack Size
0.625 in.
Core Stack Type
Interleave (1x1)
Secondary Insulation
Polyester electrical varnish
Dielectric Strength
500Vrms
Temperature Range
-40°F (-40°C) to 221°F (105°C)

Compliance

RoHS
Yes
REACH
Yes
CMRT
Yes
GPSR
Yes

Other

Country of Origin
United States
Harmonized System (HS) Code
8504.31

⚠ WARNING ⚠

These electronic components are designed exclusively for indoor or enclosed environments. It is crucial to keep them away from water and moisture to prevent damage. Transformers can generate hazardous voltages and currents, so technical electrical expertise is essential for safe use.