EDCOR Electronics Corporation
XPWR307 - 350V@235mA CT, 95V@300mA, & 10V@2A CT
Quantity:
Quantity Discounts | ||||
---|---|---|---|---|
10 pcs | 25 pcs | 100 pcs | 500+ pcs | |
5% off | 10% off | 15% off | 20% off | |
Orders over 25 pcs may take longer. Please contact us for scheduling and dates. |
Get shipping cost estimate in cart.
Specifications | |
---|---|
Series |
|
Model (SKU) Part/Model Number
|
XPWR307-120/240
|
Primary |
|
Secondary |
|
Total Volt Amperes |
|
Termination |
|
Mounting |
|
Mounting Orientation |
|
End Bell Color |
|
Winding Configuration |
|
Leakage Inductance Calculated value. Actual value may very.
|
|
Temperature Rise Calculated value. Actual value may very.
|
120V - 73.27°F (22.93°C) and 240V - 73.28°F (22.93°C)
|
Primary | |
Voltage |
120V and 240V
|
Operational Frequency |
|
Current Maximum current.
|
120V - 1.171A and 240V - 0.586A
|
DC Resistance Calculated value. Actual value may very.
|
120V - 1.825Ω and 240V - 7.306Ω
|
Inductance Calculated value. Actual value may very.
|
120V - 0.701H and 240V - 2.805H
|
Secondary | |
Tube Voltage |
350V
|
Other Voltage(s) |
95V and 10V
|
Bias Voltage Voltage tapped off of the tube voltage.
|
95V
|
Unloaded Voltage(s) Calculated voltage when no loaded is applied to the secondary. Actual value may very.
|
376.316V, 102.105V, and 11.053V
|
Current Maximum current for each secondary.
|
0.235A, 0.3A, and 2A
|
DC Resistance Calculated value. Actual value may very.
|
33.478Ω, 5.411Ω, and 0.088Ω
|
Inductance Calculated value. Actual value may very.
|
120V - 0.701H and 240V - 2.805H
|
Physical | |
Weight |
6.2 lb
|
Dimensions (Width) X (Height) X (Depth)
|
|
Dimensional Drawing (#) |
|
Dimension Drawing (PDF) Free Adobe Acrobat Reader can be downloaded at Adobe.com.
|
|
3D Model (STEP) |
|
Material | |
Bobbin Material |
|
Bobbin Flammability Rating |
|
Magnet Wire |
|
Coil Finish Wrapper |
|
Termination |
|
Core Material |
|
Core Material Size |
|
Core Stack Size |
|
Core Stack Type |
|
Secondary Insulation |
|
Dielectric Strength |
|
Temperature Range |
|
HIPOT Primary-Secondary |
|
Compliance | |
RoHS Restriction of the Use of Certain Hazardous Substances in Electrical and Electronic Equipment.
|
|
REACH Registration, Evaluation, Authorization and Restriction of Chemicals in EU.
|
|
CMRT RMI Conflict Metals Reporting Template
|
|