EDCOR Electronics Corporation
XPWR117 - 360V@500mA CT & 12V@6A
Quantity Discounts | ||||
---|---|---|---|---|
10 pcs | 25 pcs | 100 pcs | 500+ pcs | |
5% off | 10% off | 15% off | 20% off | |
Orders over 25 pcs may take longer. Please contact us for scheduling and dates. |
Classic Tube Power Transformer.
120V, 60Hz. or 240V, 50Hz. to 360V@500mA CT & 12V@6A.
Basic Specifications | |
---|---|
Series |
|
SKU Model Number/Unit Name
|
XPWR117-120/240
|
![]() Free Adobe Acrobat Reader can be downloaded at Adobe.com.
|
|
![]() Free Adobe Acrobat Reader can be downloaded at Adobe.com.
|
|
Primary Input
|
|
Secondary Output
|
|
Termination Such as lead wires, terminals, PCB pins, etc.
|
|
Mounting |
|
Mounting Orientation Direction of mounting.
|
|
Mounting Hardware Coating |
|
Mounting Hardware Color |
|
Primary (p) | |
Voltage Symbol: Ep
|
120V and 240V
|
Impedance Symbol: Zp
AC resistance
|
0.364H, and 1.455H
|
Operational Frequency Symbol: ƒop
|
|
Current Symbol: Ip
Maximum primary current
|
2.205A and 1.103A
|
DC Resistance Symbol: Rp
|
1.105Ω and 4.423Ω
|
Inductance Symbol: Lp
|
0.364H, and 1.455H
|
Secondary | |
Tube Voltage Symbol: Es
|
360V
|
Other Voltage(s) Symbol: Es
|
12V
|
Unloaded Voltage(s) Symbol: NL(Es)
Calculated voltage when no loaded is applied to the secondary.
|
377.822V and 12.475V
|
Current(s) Symbol: Is
Maximum secondary current(s)
|
0.5A and 6A
|
DC Resistance Symbol: Rs
DC Resistance
|
15.911Ω and 0.048Ω
|
Inductance (Ls) Calculated value. Actual value may vary.
|
0.364H, and 1.455H
|
Other Specifications | |
Total Volt Amperes Symbol: VA
|
|
Winding Configuration Type of winding pattern.
|
|
Leakage Inductance Symbol: LI
Imperfect magnetic link of one winding to another.
|
|
Temperature Rise Symbol: Tr
The temperature rise above the ambient temperature at rated power.
|
120V - 80.75°F (27.09°C) and 240V - 80.76°F (27.09°C)
|
Efficiency Symbol: η
The efficiency of the transfer of energy from the primary to the secondary.
|
|
Physical | |
Weight Symbol: Wt
|
8.8 lb
|
Dimensions (Width) X (Height) X (Depth)
|
|
Dimensional Drawing (#) |
|
Dimension Drawing (PDF) Free Adobe Acrobat Reader can be downloaded at Adobe.com.
|
|
3D Model (STEP) STEP (Standard for the Exchange of Product Data), an ISO standard exchange format.
|
|
Material | |
Bobbin Material |
|
Bobbin Flammability Rating |
|
Magnet Wire |
|
Coil Finish Wrapper |
|
Termination |
|
Core Material |
|
Core Material Size |
|
Core Stack Size |
|
Core Stack Type |
|
Secondary Insulation |
|
Dielectric Strength |
|
Temperature Range |
|
HIPOT Primary-Secondary |
|
Compliance | |
RoHS Restriction of the Use of Certain Hazardous Substances in Electrical and Electronic Equipment.
|
|
REACH Registration, Evaluation, Authorization and Restriction of Chemicals in EU.
|
|
CMRT RMI Conflict Metals Reporting Template
|
|
GPSR The General Product Safety Regulation (GPSR) is a legislative framework established by the European Union.
|
|
Other | |
Country of Origin Where the product was manufactured or assembled.
|
|
Harmonized System (HS) Code Standardized numerical system classifying traded products.
|
|
Please note that some specification values are calculation and may vary from the actual values
⚠ WARNING ⚠
These electronic components are designed exclusively for indoor or enclosed environments. It is crucial to keep them away from water and moisture to prevent damage. Transformers can generate hazardous voltages and currents, so technical electrical expertise is essential for safe use.